Road Access Requirements

Editorial review

A-004 · R01 · Awaiting human acceptance

Send feedback on this article
On this page
  1. What counts as access?
  2. Residential buildings
  3. Resorts, hotels and industrial buildings
  4. A plot without adequate access

Road width can limit the number of dwellings, hotel rooms or industrial storeys a plot can support even when its zone permits more floor area. The rules distinguish the road that exists from the right of way reserved for future widening.

What counts as access? #

Access means entry to a building, plot or land. A street includes a road, footpath, court-alley or passage accessible to the public temporarily or permanently. A public street is defined by public right of way, public works or expenditure, or its statutory status and includes roads of an approved subdivision. A private street is one that is not public. Annexure XII uses “public road”; Regulation 2 defines “public street”. A private passage used by an owner cannot be assumed to meet the public-road condition. [Regulation 2(11), (101), (103), (128).]

Right of way includes carriageway, shoulders, drains and footpaths and is measured at right angles to the road direction. Road embankment width is additional. [2(113), Chapter 28 Sketch 1.]

Residential buildings #

A dwelling unit has independent living, cooking and sanitary facilities. Both the number of units and the total floor area of all buildings matter. The more restrictive criterion determines the minimum existing road width. The single-dwelling row expressly requires a public road even at 3 m. The printed heading ‘PUBLIC ROADS’ also covers the remaining residential rows below it. The proponent leaves the widening prescribed in the Regional Plan or Outline Development Plan; Annexure XII also specifies not less than 6 m for other roads. [2(50), Annexure XII residential table and note.]

Residential road widths and limits

Existing road

Dwelling units

Total maximum floor area

≥3 m, public road

1

500 m²

>3 through 4 m

2

400 m²

>4 through 5 m

4

600 m²

>5 through 6 m

8

1,000 m²

≥6 m

180

20,000 m²

≥8 m

>180

>20,000 m²

Editor’s note. At exactly 6 m the printed bands overlap. The applicable row matters if the proposal exceeds eight units or 1,000 m². The table does not establish a private 3 m approach as equivalent to the single-dwelling public-road entry.

Resorts, hotels and industrial buildings #

A resort or hotel up to 2,000 m² and 40 rooms needs a 6 m existing road. Above 2,000 m² or 40 rooms the more restrictive criterion calls for 8 m. The planned road must be at least 8 m and the prescribed widening must be left. [Annexure XII, commercial table and note.]

For small industry the table pairs 1,000 m² and two storeys with a 6 m existing road, and 2,000 m² and two storeys with an 8 m road. Other industry requires 10 m, with floor area and storeys governed by the permissible height. Small scale means the classification by Government from time to time and excludes industries in the First Schedule to the Factories Act, 1948. The instrument dated 29 August 2025 removed the industrial note’s most-restrictive-criterion sentence. On 24 December 2025 the separate proposed 10 m road requirement was removed. The September 2025 Gazette carrying the 29 August instrument and the 24 December 2025 Gazette should be read in sequence. The existing-road table and obligation to leave widening under the Regional Plan or Outline Development Plan remain. [Annexure XII, industrial table and amended note.]

A plot without adequate access #

A landlocked plot is bounded on all sides by plots in different ownership and lacks public-road access. Regulation 4.11 covers no access or inadequate access. A traditional access is a pathway no wider than 1.5 m through private or public property used to reach property with no other access. [2(79), (139).]

For traditional access through another owner’s land, or proposed access 3 m wide or less, only residential G+1 development up to 200 m² floor area is allowed. For proposed access over 4.5 m and below 6 m, the residential G+1 limit is 350 m². Both routes must appear on the site plan. Editor’s note. These two proposed-width branches do not assign a limit for over 3 m through exactly 4.5 m. [4.11(a)–(b).]

Where another owner voluntarily provides an access road at least 3 m wide with the concurrence of the Authority, Council or Panchayat, that area stays in the providing plot’s FAR and coverage calculation. If access is unavailable voluntarily, the landlocked owner may request acquisition by the Authority, Council, Panchayat or TCP Department based on micro-planning. The access cannot exceed 6 m or make the affected plot unfit for development. The requesting owner bears acquisition cost plus 5% service charges, with minimum ₹5,000 or as decided by the authority from time to time. Where the acquisition prevents full FAR use due to coverage, setbacks or similar restrictions, the authority may relax those requirements on individual merit. [4.11(c)–(d).]

Development may not deprive another plot of access or an easement or reduce it below 3 m. It may pass through a setback if free of projections, and is retained in effective plot area. Temporary and permanent structures cannot encroach on public or traditional access. [4.2(i)–(j).]

Road right of way can differ from the width of the carriageway alone. The road bands for additional FAR and height do not displace Annexure XII. Access and Circulation Within a Plot explains how the route continues inside the plot. A high-rise also needs the 10 m main street and fire access required by 15.1.2. See Floor Area Ratio for the separate grant conditions.

See the official GLDBCR, Annexure XII and Regulations 4.2 and 4.11. Verify the current official regulations before making a regulatory decision.