Agricultural and Agro-Based Development
A-022 · R01 · Awaiting human acceptance
On this page
A farmhouse is tied to farming on agricultural land. Greenhouses, cold stores and animal sheds have separate allowances. A plot that meets an area threshold can still be unsuitable because of its survey classification, slope, drainage or intended use.
What the farmhouse provision covers #
Regulation 2(56) connects a farmhouse, farmer’s residence, farm sheds and auxiliary poultry or animal sheds to farming activities. Annexure XI allows residence of the owner and farm workers, storage of produce, agricultural equipment, manure and pesticides for farming, smoke houses, parking of the owner’s tractors and vehicles and allied agricultural uses. Godowns and commercial uses such as clubs, hotels and casinos are excluded.
The minimum plot area is 4,000 m². Coverage is 10%, subject to a maximum 1,000 m² built-up per holding. Farmhouse built-up area may not exceed 1,000 m² regardless of holding size. Item 3 specifies FAR 10 where plot area exceeds 10,000 m², subject to 1,000 m² built-up. Editor’s note. Item 3 expressly says “exceeds” 10,000 m². It does not itself specify a standalone FAR for smaller eligible holdings. Coverage is a separate calculation.
Maximum height is 7.60 m from ground to roof eaves, including stilts; relaxation may be considered for specific smoke-house or similar requirements. Only one farmhouse per holding is permitted. Above 20,000 m² additional non-habitable auxiliary structures may be permitted within the note’s 5% maximum coverage. [Annexure XI, items 1–4 and notes.]
Location, access and setbacks #
Farmhouses are excluded on low-lying agricultural land recorded as rice or on forest land. Table VIII Note 4 specifically excludes land classified as rice/paddy or forest. Annexure XI allows consideration of a pump house up to 6 m² and 1.8 m high in the areas described there. No hill cutting is allowed. The farmhouse belongs on a portion with slope no greater than 25%, with cutting limited to plinth, foundation and footings. Access, walls and structures cannot block natural drainage.
Item 5 sets a 6 m road right of way or a katcha carriageway at least 3 m wide, with gradient no steeper than 1:6. The note separately refers to 6 m right of way for a single farmhouse. Editor’s note. A 3 m carriageway and a 6 m reservation measure different things; the note leaves the application to a particular access to be established.
On a main village road, MDR, SH or NH the front setback is the lesser of 30 m and three quarters of plot depth, measured from the right-of-way line. Prescribed SH/NH setbacks must still be maintained. Insufficient plot depth can support consideration of front-setback relaxation. Other setbacks are at least 5 m with no projections. The roadside compound wall is limited to 1.5 m comprising 0.9 m solid and 0.6 m mesh; other sides may be solid. The house requires a sloping roof with Mangalore tile cladding and should harmonise with its surroundings. The annexure permits other roofing materials for farm, poultry or animal sheds and favours local construction materials where possible. Applicable current material and health rules govern their specification. [Annexure XI, items 5–7 and notes.]
Agro-based structures #
Annexure XI-A distinguishes eight activities. The table’s FAR is expressed against net plot area; fixed areas and a blank FAR cell have their own meaning. A dash supplies no numerical entitlement. The protected-cultivation entry also describes Agriculture Department assistance against standard costs with a cap keyed to 4,000 m² plot area. Current subsidy eligibility depends on the operative scheme.
Agro-based activities and limits
Item and activity | Minimum structure area as printed | Structure | FAR on net plot / permitted area |
|---|---|---|---|
1 Protected cultivation: greenhouse, shade/net house, plastic tunnel | “500. mts.” (unit as printed) | Tubular steel/plastic, wooden or plastic tunnel | 50% |
2 Grading and packing | As per project; area column — | Temporary/permanent | 5% |
3 Pre-cooling/primary processing | 200 m² | Temporary/permanent | 5% |
4 Cold storage | As per project | Temporary/permanent | 15% |
5 Mushroom production | As per project | Temporary/permanent | 30% |
6 Pump house with tool/input storage | 30 m² | Temporary/permanent | 30 m² permitted |
7 Water tank, 10 m³ storage | — | Temporary/permanent | — |
8 Dairy/poultry/piggery | 300 m² | Temporary/permanent | 20% |
The ordinary minimum holding is 4,000 m², except pump houses and dairy farming. Dairy may be relaxed to at least 1,000 m² of land with at most 100 m² of structure if surrounded by agricultural areas and preferably away from dense habitation. Prior approval of the Director of Agriculture or Animal Husbandry, as applicable, must be accompanied by a project report.
In wet cultivated paddy fields, items 2, 3, 4 and 8 may not be permitted. Items 1 and 5 may be permitted only with temporary structures. Front setback may be relaxed to 10 m from the right-of-way line; other setbacks follow the farmhouse guidelines. A ground-floor-only staff/labour residence up to 6 m to ridge and 50 m² maximum may be permitted only as auxiliary to the main use and outside wet cultivated paddy fields. Toilets may be permitted for items 1–5 and 8. The permitted structures can be additional to other structures allowed under the regulations on that plot. [Annexure XI-A, Notes 1–8.]
Agricultural zone use limits #
The 13 August 2026 Gazette replaces 6A.2.1. In A1/A2 it prohibits uses other than agriculture, horticulture, farming and allied operations, subject to the specific roads, subdivision, ancillary-use and institutional provisions. Agricultural research/development centres, agricultural educational or educational institutions and biotechnology units require at least 200,000 m²; yoga or meditation centres require at least 50,000 m². For both groups the upper limits are 5% coverage, FAR 5 and 7.60 m height. These specific uses do not enlarge the farmhouse allowances. See Planning Areas, Zones and Land Use for the amended zone framework and Site Constraints and Sloping Land for general slope and drainage conditions.
See the official GLDBCR, Annexures XI and XI-A and Table VIII Note 4. Check the current official regulations and applicable notifications before making a regulatory decision.