  1. From survey area to effective plot area
  2. What counts in the footprint?
  3. Calculate coverage and compare it with the zone limit

The part of a plot occupied by a building is controlled separately from the total floor area allowed across all storeys. The starting figures are the area measured just above plinth and the land that remains after the statutory deductions.

From survey area to effective plot area #

Regulation 2(51) starts with the plot area in the survey records. This effective plot area is the denominator for both coverage and FAR. It deducts the proposed road rights of way, areas reserved for public purposes (except areas earmarked for easement rights or traditional access), areas where development is not permitted in A1, A2, R and P, and mundcar areas under the Mundcar Act. The third deduction turns on whether development is permitted in the area concerned. Regulations 4.2(i) and 4.11(c) separately address when access land is retained in the effective area. The conditions are explained in Road Access Requirements.

What counts in the footprint? #

Covered area is the area covered by the building or buildings immediately above plinth level. Regulation 2(43)(a)–(g) excludes the following, within their stated limits.

Balconies need at least 2.25 m clear height above ground. Unstoried porches are excluded up to 25% of total covered area. Atriums and podiums in commercial and residential buildings are limited to 30% of total covered area.

The listed site elements include septic tanks, soak pits, manholes, drainage, gutters, chambers, wells and similar works, fountains, steps, sumps, rainwater harvesting tanks, pump houses no larger than 6 m², swing frames, compound walls and gates, transformers, generators, compost pits, security cabins no larger than 6 m², and antennas and bases. Their location must keep vehicle movement and parking clear.

An uncovered swimming pool qualifies on a plot over 2,000 m², or on a plot below 2,000 m² where the pool does not exceed 10% of plot area. Free vehicle movement and parking must remain possible. Editor’s note. Clause (d) gives neither branch for a plot of exactly 2,000 m².

The basement exclusion concerns the part beyond the permissible coverage building line or footprint. The telecommunications exclusion covers covered antennas, dish antennas and communication towers used for basic cellular or satellite telephone or IT purposes, including earth-station, V-Sat, transponder and similar equipment. The exemption is tied to the item and use. A floor-area exemption by itself does not remove a building footprint from coverage.

Calculate coverage and compare it with the zone limit #

Coverage (%) = covered area × 100 ÷ effective plot area. If survey area is 1,000 m², a proposed road right of way takes 100 m² and there are no other deductions, a covered area of 360 m² gives 40% coverage. The calculation supplies the proposal’s percentage. Building Regulations by Zone sets out the relevant permitted limits, including the industrial entries amended on 29 November 2024. Conservation zones may instead be subject to their special limits in Table IX. [2(44), 6A.4, Table VIII and notes.]

Annexure XIII-A Note 13 uses total net effective plot area for calculating additional FAR. A grant of additional FAR or height under 6.1.2 gives no general increase in coverage. See Floor Area Ratio for exclusions at individual floors and the grant conditions.

See the official GLDBCR, Regulation 2(43), (44) and (51), and the 24 November 2026 Gazette, Annexure XIII-A Note 13. Check the current official regulations and notified plan before making a regulatory decision.