Group Housing, Shopping Malls and Multiplexes

Editorial review

A-013 · R01 · Awaiting human acceptance

Send feedback on this article
On this page
  1. Buildings sharing a plot
  2. When a shopping complex is a mall cum multiplex
  3. A landmark tower within the complex

Shared open space, internal roads and parking are part of the layout of a group of buildings. An integrated shopping mall with a multiplex has a different test, beginning with its commercial location, site size, road width and cinema screens.

Buildings sharing a plot #

A group of buildings means more than one building on one plot. It may consist of residential buildings, shops, offices or a combination. Open space is an area of the site left open to the sky, including subdivision land reserved for recreation or another permitted public use. [Regulation 2(69), (94).]

Regulation 5 applies its main open-space provision where effective plot area is more than 4,000 m² and less than 20,000 m². For a building or group of buildings, the subdivision open space under Regulation 12 is additional to parking. Subdivision and Plot Layout explains how that open space is treated. It remains in the effective plot area for FAR and coverage. Clause (a) excepts a single-family dwelling.

Every building needs at least 3 m access with 1.5 m setback on each side of that access. Parking areas must be served by an internal road at least 6 m wide. Where parking is within a building, that building also needs 6 m access and 1 m setback from the road. A 6 m road must extend to the rear or adjoining plot if that plot lacks access. The general road-setback provisions do not apply to this extension. No building part, including a balcony, may project over the road or access. See Access and Circulation Within a Plot for ordinary access rules. [5(b)–(d), (g).]

Commercial use follows 6A.1 and the current land-use restrictions. For plots over 20,000 m² the internal roads must follow the subdivision rules or a road hierarchy, subject to 5(a)–(d). High-rise fire requirements also apply. Fire Safety and Life Safety explains vehicle access and egress. Editor’s note. The text uses strict bounds at 4,000 and 20,000 m². In particular, 5(f) begins above 20,000 m², while the opening provision ends below it. [5(e)–(g) and note.]

When a shopping complex is a mall cum multiplex #

The integrated shopping and entertainment complex must have at least two cinema screens in the complex or a separate building in the same compound. Its other uses may include retail, food courts, pubs, bowling, restaurants, health centres, conventions, hotel, IT/ITES and recreation. A new complex requires at least 10,000 m² and an existing abutting road at least 15 m wide. The statutory plan must designate a notified commercial area. A qualified traffic and transportation consultant must prepare a traffic impact study and traffic management plan. The authority considering building permission requires a Fire and Emergency Services NOC. [5A(1)–(3).]

Coverage is 50%. FAR and ordinary permissible height follow the zone. For assembly occupancy the lower of the zone height and 30 m applies. Parking is one equivalent car space per 35 m² of built-up area. [5A(4)–(5).]

A landmark tower within the complex #

Board approval can be considered for an iconic or landmark tower of tourist or public interest enhancing the city image, with the required setbacks, only in C1 Special, CS or SPC. The tower must have non-assembly occupancy, a maximum height of 50 m and an area no greater than 33% of the overall plinth area of the mall cum multiplex. An attached tower requires separate ground-level entry and exit and the entire building including the tower may not exceed 50 m. A detached tower in the same compound may be considered independently up to 50 m. The relaxation depends on availability of suitable high-rise fire equipment through the Director of Fire and Emergency Services. Exemption may be considered where the developer donates the equipment required by Government and provides in-house firefighting. [5A(4) and note.]

See the official GLDBCR, Regulations 2(69), (94), 5 and 5A. Check the current official regulations and notified plan before making a regulatory decision.