Rooms, Lighting and Ventilation
A-014 · R01 · Awaiting human acceptance
On this page
Room standards start with how a space will be used. Area, width, ceiling height and openings are separate tests. A room can satisfy the minimum floor area and still be too narrow, too deep for the available light or too low under a sloping roof.
Living and sleeping rooms #
Carpet area measures usable covered space excluding the walls. Ceiling height is measured from the floor to the slab underside. A habitable room is occupied or intended for study, living, sleeping or eating; the definition excludes kitchens, bathrooms, WCs, stores, laundries, service/storage pantries, corridors, cellars, attics and other spaces not frequently or extensively occupied. External air is space open to the sky. [2(28), (29), (54), (70).]
Ordinary habitable rooms need at least 10 m² carpet area, 2.5 m width and 2.8 m height to the finished underside of slab or ceiling. Under a sloping roof no point may be below 2.1 m. Up to one quarter of the room area may be 2.2 m wide if a wall of that part opens directly to external air. Recognised educational, cultural or sports institutional/association hostels may have 8 m² rooms. For EWS housing by Government, semi-government or public/local authorities the 8 m² relaxation may be permitted. Stores, laundries or prayer rooms lacking ordinary light/ventilation may be 3–5 m². Above 5 m² and for rooms otherwise unspecified the habitable-room size and ventilation rules apply. [13.1–13.2; Sketch 4.]
Rooms over 5 m high count twice their area for FAR, with operational exceptions for institutional/religious buildings, theatres, auditoriums, atriums, foyers, industrial buildings and like cases. Telematic equipment storage/erection facilities in IT/ITES may have the height necessary for operation. In industrial estates/areas the Factories Act and rules govern minimum height and roofing; greater height is permitted. [13.1(b)–(d).]
Daylight and air #
Windows, fanlights and similar openings directly to external air, balcony or verandah must total at least one tenth of carpet area, including frames and excluding doors. Hospital wards, dormitories and schools use one sixth of floor area. Room area over 7.5 m from the external façade is generally treated as unlit. The exception for cultural/institutional buildings, commercial offices, banks and like buildings requires window area of one sixth of floor area, frames included and doors excluded. Cross-ventilation may be provided to at least one habitable room of a dwelling using opposite or adjacent walls. [13.3.]
Bathrooms and kitchens #
Bathrooms and WC compartments
Arrangement | Minimum floor area | Minimum short side | Opening to external air |
|---|---|---|---|
Combined bath and WC | 3 m² | 1.25 m | 0.80 m² |
Separate bathroom | 1.50 m² | 1 m | 0.60 m² |
Separate WC | 1.25 m² | 1 m | 0.50 m² |
A water closet is a flushed fixture connected to the sewage system; the term also covers its compartment. Each compartment needs 2.2 m ceiling height and at least one wall open to external air, an open balcony or verandah no wider than 2 m, or the prescribed interior open space. In cultural/educational institutions, cinemas and hotels an internal arrangement may be allowed within a room opening directly to external air with openings of at least one tenth of its floor area, room height at least 2.5 m and compartment partitions no higher than 2.2 m. [2(148), 13.4(a).]
For hotel passage ventilation the passage must be at least 1.8 m wide. The exhaust duct must measure at least 0.8 m on the shorter side and 1.5 m on the other, ventilated at top and bottom and accessible at ground level except where mechanical ventilation is used. A slab or loft above a bath/WC may start above 2.2 m. The WC room is for lavatory use alone, must close completely by door and cannot open directly into a kitchen. Floors must be impermeable and drain to the building sewer. A bath or WC above or below another room requires a watertight floor unless the other space is another bath, WC, washing place or terrace. Brick, stone or similar partitions need smooth impervious finish or suitable tiling to at least 1 m above floor. Industrial units in estates/industrial areas require separate ladies’ and gents’ toilet blocks in addition to factory requirements. [13.4(a)–(c) and notes.]
Minimum sanitary provision by use
Use | Required provision under 13.4(d) |
|---|---|
Dwelling | One bathroom and WC, separate or combined |
Shops | One WC and urinal per six shops or part, plus one ladies’ WC |
Godown, service garage, workshop, petrol pump with/without service station | One WC and one urinal per building |
Cinema, theatre, public assembly | At each seating level: one WC per 100 seats or part, two urinals per 75 seats or part. At least two washbasins per block; apportion between men and women. |
School, college, institution | One WC per 100 students or part, two urinals per 150 or part, plus washbasins |
Market, business, office, bank, restaurant | One WC and one urinal per 100 m² floor area or part |
Residential hotel, lodging house; hospital or nursing home | One WC and one bathroom per 50 m² floor area or part, plus washbasins |
Industrial premises | One WC per 150 m² floor area or part, plus washbasin |
A separate kitchen needs 7 m² carpet, 2 m width, 2.8 m height except the portion accommodating an upper-floor toilet drop or trap, and at least 2.5 m at any point under a sloping roof. It requires an impermeable floor and windows at least one tenth of carpet area. An open kitchen may occupy at least 3 m² in addition to the habitable-room area, without a partition and with light and ventilation adjacent to that area. A dwelling needs a living room, kitchen and WC. In the specified public EWS housing a common institutional toilet may be permitted instead. [13.5, 13.7.]
Shops and entrance levels #
A shop needs at least 6 m² carpet area and 2 m least dimension. From 6 to 9.99 m² no mezzanine is permitted and frontage/width is at least 2 m. At 10 m² and above, width is at least 2.5 m. The printed shop-size bands leave dimensions between 9.99 and 10 m² without a stated special rule. Shops need a full front opening for ventilation. Mezzanines, Lofts, Attics and Basements explains the general mezzanine requirements. Deeper than 7.5 m, additional ventilation is required from another side to habitable-room standards unless mechanically ventilated. [13.6.]
The plinth is the portion between surrounding ground and the floor immediately above. For residences, it is at least 45 cm above the top surface of the pathway or access near the entrance. The competent authority may relax this for other buildings; the ground floor may be on stilts or pillars. A sanitary block, pump or air-conditioning plant room may have a 45 cm minimum plinth; a vehicle-parking garage may have none. [2(99), 13.9.]
See the official GLDBCR, Regulations 13.1–13.7 and 13.9 and Chapter 28, Sketch 4. Stairs, Lifts and Accessibility covers accessible WCs. Check the current official regulations before making a regulatory decision.