  1. How much parking is required?
  2. Bay size and circulation
  3. Stilt parking, separate structures and electric vehicles

Parking depends first on the use served. Some entries specify a number of spaces, others an area of parking. In either case the driveway and manoeuvring space must allow vehicles to reach and leave the bays.

How much parking is required? #

Regulation 10(a) applies to every new building and to additions to an existing building. A parking space may be open or covered, enclosed or unenclosed, and must have driveway access to the street, road or alley for vehicles to enter and leave. [2(96), Table IX-A.]

Minimum off-street parking by use

Use

Minimum parking

Dwelling unit ≤75 m²

1 space per unit

>75 through 100 m²

1.25 spaces per unit

>100 through 150 m²

1.5 spaces per unit

>150 m²

2 spaces per unit

Four- and five-star hotels

1 space per 2 rooms

Other hotels and motels

1 space per 4 rooms

Cinemas, theatres, dance and public assembly halls

1 space per 20 m² floor area or part

Retail business markets including restaurants, offices, professional offices, banks, hospitals and nursing homes

1 space per 50 m² floor area or part

Wholesale warehousing, wholesale markets and market yards

50 m² parking per 100 m² floor area or part

Schools and colleges

25 m² parking per 100 m² floor area or part

Industrial premises

50 m² parking per 200 m² floor area or part

Stadia

50 m² parking per 50 seats or part

Retail markets

25 m² parking per 100 m² floor area or part

Editor’s note. Table IX-A includes retail business markets in IV and retail markets in IX, on different measurement bases. The intended classification matters. The residential entries also give fractional spaces per unit without an express rounding rule in the table.

Bay size and circulation #

One off-street space measures at least 2.5 m × 5 m (12.5 m²). Circulation and manoeuvring room is additional. Required parking areas cannot be converted to open spaces. The layout accompanies the application. Street access is at least 3 m wide and kept free of parking. Above 19 parking spaces two independent street accesses are required, although one may be permitted if at least 5 m wide and kept free of parking. [10(b)–(c).]

Basement parking requires at least two adequately sized and sloped ramps, preferably at opposite ends. A single ramp may be permitted at 5 m width or more. Where a ramp is infeasible a car lift is the alternative. Regulation 2(110) defines a ramp with maximum gradients of 1:6 for motorised and 1:12 for pedestrian traffic. The internal driveway in 4.2(f) has a stricter “less than” gradient. Annexure VI separately deals with basement parking and access, including its 10 m access-road provision. Regulation 15.9.10(k) sets a separate fire rule for vehicular basement ramps: at least two 3.60 m ramps, preferably opposite, with maximum 1:8 gradient. Editor’s note. The fire rule contains no express single-ramp exception. A single wide ramp under 10(f) cannot be presumed sufficient where the fire rule governs. See Fire Safety and Life Safety and Mezzanines, Lofts, Attics and Basements. [10(f).]

Stilt parking, separate structures and electric vehicles #

Ground-floor stilt parking, in full or part, may be exempted if the developer provides a separate parking-only structure on the same plot. That structure is free of FAR, counts in coverage and must comply with all other regulations. Surplus off-street parking may support favourable consideration of relaxation of other requirements, excluding FAR, coverage, height and setbacks. [10(d)–(e).]

New and renovated non-residential buildings and the other residential buildings, cooperative housing societies and RWA-managed colonies described in 10(g) with more than ten equivalent car spaces require at least 20% of those spaces to be EV-ready, with conduits under the Goa Electric Mobility Promotion Policy 2021 as amended. An independent house on a single holding is exempt. Where Regulation 16 applies, it specifies two signed accessible spaces per 25 car spaces or part, each at least 3.6 m wide and within 30 m travel of the entrance. See Stairs, Lifts and Accessibility. [10(g) and note.]

An applicant seeking additional FAR or height has to ensure adequate parking for the additional floor area before application under 6.1.2(c)(iii). The 24 November 2026 Gazette retains the ordinary parking schedule. Group Housing, Shopping Malls and Multiplexes explains the separate requirement of one equivalent space per 35 m² built-up area under 5A(5).

See the official GLDBCR, Regulation 10 and Table IX-A. Verify the current official regulations before making a regulatory decision.